Journal figure requirements

Science Figure Guidelines

What a final Science figure has to meet: the three print widths, image resolution, lettering, part labels and the file types production accepts. Summarized from Science’s author instructions, with the pixel counts already worked out.

Checked against the official guide on November 25, 2026

184 mm121 mm57 mm
Three columns · 184 mmTwo columns · 121 mmOne column · 57 mmA4 sheet, 210 × 297 mm

In short

Science prints figures 5.7 cm wide for one column, 12.1 cm for two columns or 18.4 cm for the full three-column width. Grayscale and color images need at least 300 dpi at that size, and line art that is not vector needs at least 300 dpi too, with more preferred for both. Lettering is about 7 pt after reduction and never below 5 pt, preferably in Helvetica, and part labels are 10 pt bold capitals. At revision each figure goes in as its own file: PDF, EPS or AI for vector art and TIFF for raster images. PowerPoint files and figures embedded in Word are not accepted.

Figure specifications

Every value is taken from the official guide linked above. Notes give the detail the guide adds around each rule.

ItemRequirement
Figure width5.7 cm (1 column), 12.1 cm (2 columns), 18.4 cm (3 columns)Bar graphs, simple line graphs and gels may be printed narrower than one column.
Image resolutionGrayscale and color images at least 300 dpi at final sizeHigher if possible. Upsampling an image to raise its resolution is not permitted.
Line artVector where possible, otherwise at least 300 dpi at final sizeA higher resolution is preferred for raster line art.
Initial submissionFigures embedded in the .docx or PDF manuscript, images at 300 dpiKeeps the file size manageable; separate figure files follow at revision.
Preferred formatsPDF, EPS or AI for vector illustrations and diagramsVector files can be resized for the page without losing quality.
Raster filesTIFF for raster illustrations, photographs and microscopyFigures that combine vector and raster parts, such as labeled micrographs, go in as PDF or EPS.
Not acceptedPowerPoint files and figures embedded in WordNor any file that Photoshop or Illustrator cannot open.
FontsSans-serif, Helvetica preferredVariables in italics or plain Greek letters, other text plain or bold. Avoid colored type, and set type over a colored area in bold.
Text sizeAbout 7 pt (2.5 mm) after reduction, never below 5 ptAvoid wide variation in type size within one figure.
Part labels10 pt bold capitals A, B, CIn the upper left corner of each part, inside the frame when the part is an image. Avoid subpart labels.
Lines and symbolsLines at least 0.5 pt, symbols at least 6 pt at final sizeSolid symbols are preferred unless data overlap or several symbol types are needed.
Scale barsScale bars instead of, or as well as, magnificationsUse white type and white scale bars over darker areas of an image.

Sources: Instructions for preparing an initial manuscript, Instructions for preparing a revised manuscript. An independent summary, not affiliated with AAAS; the journal’s current instructions take precedence.

Pixels you need at each width

Width in mm ÷ 25.4 × dpi, to the nearest pixel, as publishers count it. Export at least this many pixels across for the column you are aiming at.

Width300 dpi
One column · 57 mm673 px
Two columns · 121 mm1,429 px
Three columns · 184 mm2,173 px

Worth knowing

  • Science asks for figures to be built as vector files, for example in Illustrator, so they can be resized for the page without losing quality. If you work in Photoshop, keep the labels on their own editable layer.
  • Graph styling is specific: label each axis with the quantity and its unit in parentheses, such as Pressure (MPa), capitalize only the first word, add leading zeros to decimals, and leave out minor tick marks, gridlines and right-hand axis labels that repeat the left.
  • Red and green should not be used together, and parts of a figure should not be told apart by colors of similar hue. Science also asks authors to avoid grayscale and light screen shading; hatched or cross-hatched fills work for emphasis instead.
  • The figure title belongs at the start of the caption, not inside the figure. Captions open with a short bold title, describe each panel in order and stay under 200 words.
  • Contrast, brightness and color may only be adjusted evenly across a whole image; nonlinear adjustments are stated in the caption, and images assembled from several gels or micrographs need a line between the parts.

Why figures come back, and the fix

The problems that most often send a figure back from production. Where a free tool helps, it is linked under the fix.

  1. 1. Problem

    A micrograph is placed at 18.4 cm but only has enough pixels for one column.

    Fix

    At 300 dpi, 5.7 cm needs at least 673 pixels across, 12.1 cm needs 1,429 and 18.4 cm needs 2,173. Science does not permit upsampling, so export again from the original data or use the image at a smaller width.

    Image DPI Checker
  2. 2. Problem

    Labels set for a full page layout fall below 5 pt once the figure is reduced to one column.

    Fix

    Draw the figure at its printed width first, then set lettering at about 7 pt and part labels at 10 pt bold, so nothing drops under the 5 pt floor.

  3. 3. Problem

    A revised figure arrives as a PowerPoint slide or pasted into the Word manuscript.

    Fix

    At revision each figure is its own file: PDF, EPS or AI for vector art and TIFF for raster images. Export from the original drawing program; simple line art that only exists as a bitmap can be traced to vector first.

    Vectorize Image
  4. 4. Problem

    Two data series are told apart by red and green, or by two similar shades.

    Fix

    Use colors that differ clearly in hue, give each series its own simple symbol, and preview the figure as a reader with red-green color blindness would see it.

    Colorblind Simulator
  5. 5. Problem

    The figure title and long explanations are typed inside the figure.

    Fix

    Move the title to the start of the caption and keep explanatory text there too, where errors are easier to fix, within the 200 word limit.

    Figure Legend Generator

Check a figure against the Science widths

The image DPI checker reads your file in the browser, with nothing uploaded, and shows the effective dpi at 5.7, 12.1 and 18.4 cm and the pixels each width needs.

Check my figure at 57 mm

FAQ

What size should a figure be for Science?

Science prints figures at one of three widths: 5.7 cm (2.24 in) for one column, 12.1 cm (4.76 in) for two columns and 18.4 cm (7.24 in) for three. Bar graphs, simple line graphs and gels may be reduced below one column. The instructions give no maximum height but ask you to avoid wasted white space.

What resolution does Science require for figures?

Grayscale and color images need at least 300 dpi at the printed size, and more if possible. Line art that is not a vector file also needs at least 300 dpi, with higher preferred. At 300 dpi that is 673 pixels across for one column, 1,429 for two and 2,173 for three. Upsampled images are not permitted.

Which font and size should I use in Science figures?

A sans-serif font, with Helvetica preferred. Lettering should be about 7 pt (2.5 mm high) after reduction and never smaller than 5 pt, and part labels are 10 pt bold capitals (A, B, C) in the upper left of each part.

Does Science accept TIFF, JPEG or PowerPoint figures?

TIFF, yes: it is the format for raster illustrations, photographs and microscopy. Vector art goes in as PDF, EPS or AI. PowerPoint files and figures embedded in Word are not accepted, and JPEG is not among the formats listed for revised figures, outside of which Science says it cannot accept files.

How are figures submitted to Science the first time?

For the initial submission, figures are embedded in the .docx or PDF manuscript, with images saved at 300 dpi to keep the file manageable. Separate figure files that meet the revision rules are requested once the paper is returned for revision.