Free pharmacology calculator

IC50 calculator with a four-parameter logistic fit

Paste concentrations and responses, with replicates side by side, and this IC50 calculator fits a four-parameter logistic curve on log concentration. It reports the IC50 with an approximate 95% confidence interval, the Hill slope, R², the absolute IC50 and pIC50, draws the curve on a log axis, and exports PNG, SVG and CSV.

  • Free to calculate, no sign-up
  • Runs in your browser
  • % activity or % inhibition
  • Fix Bottom at 0 or Top at 100
Example data
IC50
50.46 nM
95% CI 45.1 to 56.5 nM (approximate)
Hill slope
−0.978
Negative: falls with dose
R²
0.9967
30 values, 26 df
Absolute IC50
53.13 nM
Where the curve crosses 50
pIC50
7.3
−log10 of IC50 in mol/L
IC50 = 50.46 nM (95% CI 45.1 to 56.5), Hill slope −0.978, R² = 0.9967
Kinase inhibitionDose-response curve of 10 concentrations on a log axis with a four-parameter logistic fit: IC50 = 50.46 nM (95% CI 45.1 to 56.5), Hill slope −0.978, R² = 0.9967.0.1110100100010000−250255075100125Concentration (nM), log scaleActivity (% of control)Kinase inhibitionIC50 = 50.46 nM (95% CI 45.1 to 56.5), Hill slope −0.978, R² = 0.9967Mean ± SD4PL fitIC50 (halfway between Bottom and Top)IC50 = 50.46 nM
Best-fit parameters
ParameterBest fitStd. errorNote
Bottom0.37641.057Lower plateau
Top102.21.236Upper plateau
LogIC501.7030.02377log10 of nM
Hill slope−0.97750.04963Steepness

Fitted to every replicate value by least squares (Levenberg-Marquardt). The 95% interval comes from the standard error of LogIC50 and the t distribution, so it is approximate.

Data and fitted values
Concentration (nM)MeanSDnFittedResidual
0.5081001.443101−0.991
1.52499.72.223990.707
4.57292.92.4393.3−0.396
13.7281.91.31379.92.02
41.1554.14.13356.3−2.24
123.531.20.529330.30.868
370.413.23.04313.10.16
11115.82.2135.10.697
33332.571.4632.040.524
10000−0.43.2730.952−1.35

Everything runs in your browser: your data is never uploaded.

How to use it

Calculate an IC50 in three steps

Paste your dose-response data, say what the responses mean, then read the IC50 and its curve. Everything runs in your browser.

  1. The data box with the kinase example: ten concentrations from 0.508 to 10000 nM in triplicate, and the unit set to nM
    1

    Paste your dose-response data

    Put concentrations in the first column and one column per replicate, straight from Excel, then choose the concentration unit.

  2. The response type set to % activity, with Fix Bottom at 0 and Fix Top at 100 switched on
    2

    Set the response type and plateaus

    Choose % activity, which falls with dose, or % inhibition, which rises. Fix Bottom at 0 or Top at 100 only when your controls define a plateau the data do not reach.

  3. Kinase example results: IC50 50.46 nM with 95% CI 45.1 to 56.5, Hill slope −0.978, R² 0.9967, absolute IC50 53.13 nM and pIC50 7.3, above the dose-response curve
    3

    Read the IC50

    The IC50 comes with its approximate 95% CI, the Hill slope, R², the absolute IC50 and pIC50, above the curve with the IC50 marked. Download PNG, SVG or CSV.

Four IC50 fits from the examples

Real runs of the calculator: relative and absolute IC50 on the same viability data, the effect of fixing both plateaus, a rising % inhibition curve, and the parameter table with standard errors.

Cell viability dose-response curve levelling off near 22%, with IC50 2.319 µM and absolute IC50 3.518 µM in the result tiles
Cell viability example with free plateaus: viability levels off at a Bottom of 22.12%, so the relative IC50 is 2.319 µM (95% CI 1.88 to 2.87) and the absolute IC50, where the curve crosses 50%, is 3.518 µM. Hill slope −1.42, R² = 0.9834.
Cell viability curve forced from 100 to 0, missing the points at high concentrations, above the parameter table with both plateaus fixed
The same viability data with Bottom fixed at 0 and Top at 100: the IC50 moves to 5.229 µM (95% CI 3.87 to 7.07), the Hill slope flattens to −0.763 and R² drops to 0.9407, because the curve no longer follows the plateau near 22%.
Rising % inhibition curve on a log concentration axis with the IC50 of 14.92 nM marked
Enzyme example entered as % inhibition: the curve rises, the Hill slope is positive at 0.867, and the IC50 is 14.92 nM (95% CI 11.7 to 19.1) with R² = 0.99.
Table of Bottom, Top, LogIC50 and Hill slope with their standard errors for the kinase example
Best-fit parameters for the kinase example, from 30 replicate values: Bottom 0.3764 (SE 1.057), Top 102.2 (SE 1.236), LogIC50 1.703 (SE 0.02377) and Hill slope −0.9775 (SE 0.04963).

Guide

How to calculate and report an IC50

What IC50 means, how to calculate it from dose-response data, relative versus absolute IC50, the Hill slope and fixed plateaus, why IC50 is not Ki, and how the confidence interval is found.

What IC50 means

IC50 is the concentration of an inhibitor that brings the response halfway between the top and bottom plateaus of its dose-response curve. GraphPad points out that this is not the same as the concentration that gives a response of 50. A lower IC50 means a more potent compound in that assay.

TopBottomIC50: halfwayHill slopeConcentration, log scale
Drawn from the 4PL with Top = 100, Bottom = 5, IC50 = 50 and Hill slope = −1.
  • The curve is the four-parameter logistic Y = Bottom + (Top − Bottom) / (1 + 10^((LogIC50 − X) × HillSlope)), where X is the log10 of concentration. GraphPad Prism calls it “log(inhibitor) vs. response, variable slope”.
  • Top and Bottom are the plateaus in the units of the response; LogIC50 is the log of the IC50; the Hill slope sets how steep the curve is.
  • An IC50 belongs to the assay as well as the compound: conditions such as the substrate concentration can shift it. Compare values measured under the same conditions.

How to calculate IC50 from your data

Calculating an IC50 is a curve fit across all your concentrations, not a straight line drawn between the two points on either side of 50%.

  • Normalize each response to your controls: 100% activity is the untreated control and 0% the fully inhibited or background control. % inhibition is 100 minus % activity.
  • Test a range of concentrations that brackets the IC50, with points on both plateaus, so the curve’s top and bottom are measured rather than guessed.
  • Paste the concentrations in the first column and the replicates beside them, then choose the unit and whether the responses are % activity or % inhibition.
  • The calculator fits Bottom, Top, LogIC50 and the Hill slope to every replicate value and reports IC50 = 10^LogIC50 in your unit.
  • Leave the zero-concentration control out of the table, or let the calculator drop it: a log axis cannot show zero. Use it to normalize, and fix the plateau it defines if the data do not reach that plateau.

Check the warnings

The calculator says when the IC50 lies outside the tested range, when a plateau is not reached, or when the response type looks wrong, so you can fix the data before you report a number.

Relative vs absolute IC50

The two definitions agree only when the fitted curve runs from 100 down to 0. When it levels off higher, they give different concentrations.

Halfway (61)Response = 50
Relative IC50
2.3 µM
Absolute IC50
3.5 µM
The cell viability example: the curve levels off near 22%, so halfway is about 61% and the two IC50 values differ.
  • Relative IC50: the concentration that gives a response halfway between the fitted Bottom and Top. GraphPad calls this by far the most common definition, and it is what the calculator reports as the IC50.
  • Absolute IC50: the concentration at which the curve crosses 50 on your normalized scale. It exists only when the curve passes 50, and the calculator reports it separately.
  • In the cell viability example, viability levels off near 22%. The relative IC50 is 2.3 µM and the absolute IC50 is 3.5 µM.
  • GraphPad notes that the term absolute IC50 is not entirely standard and that it does not quantify the potency of a drug. Say which one you report.

Hill slope and fixing the plateaus

The Hill slope sets how steeply the response changes around the IC50. In this equation it is negative when the response falls with concentration and positive when it rises.

  • Hill slope −0.5
  • Hill slope −1
  • Hill slope −2
Same IC50, three slopes. The steeper the curve, the narrower the range of concentrations over which the response changes.
  • GraphPad treats a Hill slope of −1 as standard for an inhibition curve. With a slope of −1, going from 10% to 90% of the full change takes an 81-fold change in concentration; with −2, a 9-fold change.
  • The size of the slope, not its sign, describes steepness: % activity data give a negative slope and the same data as % inhibition give a positive one.
  • Fix Bottom at 0 when the responses are normalized so that 0 means full inhibition and the highest concentrations do not reach it. GraphPad suggests constraining Bottom to 0 if you subtracted a basal response.
  • Fix Top at 100 when the lowest concentrations do not reach the untreated level. Do not fix a plateau the data contradict: in the cell viability example, fixing Bottom at 0 and Top at 100 moves the IC50 from 2.3 to 5.2 µM and lowers R² from 0.983 to 0.941.

IC50 is not Ki

IC50 depends on how the assay is run. Ki, the inhibition constant, describes the inhibitor’s binding and does not change with the substrate or tracer concentration.

Competitive inhibitor: IC50 rises with substrate

IC50 = Ki × (1 + [S] / Km)

  • [S] = 0.5 × Km1.5 × Ki
  • [S] = 1 × Km2 × Ki
  • [S] = 4 × Km5 × Ki
  • [S] = 9 × Km10 × Ki
Cheng and Prusoff (1973). The same inhibitor, with the same Ki, gives a higher IC50 at a higher substrate concentration.
  • For a competitive inhibitor of an enzyme, Cheng and Prusoff (1973) related the two: Ki = IC50 / (1 + [S] / Km), where [S] is the substrate concentration and Km is its Michaelis constant.
  • In a competitive binding assay the same correction uses the labeled ligand: Ki = IC50 / (1 + [L] / Kd), where [L] is the radioligand concentration and Kd its dissociation constant.
  • GraphPad notes that the correction only makes complete sense when two compounds compete for one binding site at equilibrium, which gives a Hill slope of 1 or −1. With other slopes it has no molecular basis.
  • So IC50 values from assays run at different substrate or tracer concentrations are not directly comparable, while Ki values can be.

How the confidence interval is calculated

The 95% confidence interval is approximate, and the calculator leaves it out rather than show a number it cannot support.

  • The fit uses the Levenberg-Marquardt method for nonlinear least squares on every replicate value, started from several initial guesses.
  • The standard error of LogIC50 comes from the covariance matrix of the fit. The interval is LogIC50 ± t × SE, with t from the t distribution with the number of values minus the number of fitted parameters as degrees of freedom.
  • The two ends are converted back to concentrations, so the interval is asymmetric around the IC50. GraphPad describes the same pattern: close to symmetrical on a log scale, quite asymmetrical on a concentration scale.
  • No interval is shown when the IC50 lies outside the tested concentrations, when there are no more values than parameters, or when the data cannot separate the IC50 from the other parameters.
  • We checked it on 400 simulated experiments with a known IC50 of 85 nM, triplicates at 11 concentrations and random noise: the interval contained the true IC50 in 95.3% of them.

Frequently asked questions

Quick answers on calculating IC50, doing it in Excel, EC50, pIC50, the Hill slope, missing intervals and Ki.

How do I calculate IC50?

Measure the response at a series of concentrations that brackets the IC50, normalize it to your controls as % activity or % inhibition, and fit a four-parameter logistic curve on log concentration. The IC50 is the concentration where the fitted curve is halfway between its top and bottom plateaus. Paste the data above and the calculator does the fit.

How do I calculate IC50 in Excel?

Excel has no built-in four-parameter logistic fit. You can write the 4PL equation in a column, compute the squared differences from your data, and let the Solver add-in minimize their sum by changing Bottom, Top, LogIC50 and the Hill slope. Or copy the columns from Excel and paste them here.

What is the difference between IC50 and EC50?

Both are the concentration that gives a response halfway between the curve’s bottom and top plateaus. IC50 is used for inhibitors, where the measured activity falls, and EC50 for agonists or any effect that rises with concentration. The curve fit is the same.

How do I convert IC50 to pIC50?

pIC50 is the negative log10 of the IC50 in mol/L. An IC50 of 100 nM is 1 × 10⁻⁷ M, so its pIC50 is 7; an IC50 of 1 µM gives a pIC50 of 6. The calculator shows pIC50 whenever the concentrations are in a molar unit.

What does the Hill slope tell me?

How steep the curve is around the IC50. A slope of about −1 (or 1 for % inhibition) is what a simple one-site inhibitor gives. Much steeper or shallower slopes are worth a second look: they can come from the biology, from an assay artifact, or from too few concentrations across the drop.

Why is there no confidence interval for my IC50?

The calculator leaves it out when the IC50 lies outside the concentrations you tested, when there are no more values than fitted parameters, or when the data cannot pin down the IC50 separately from the plateaus. Adding concentrations around the IC50, or fixing a plateau your controls define, usually fixes it.

Is IC50 the same as Ki?

No. IC50 depends on the assay conditions, such as the substrate concentration. For a competitive inhibitor of an enzyme, the Cheng-Prusoff equation Ki = IC50 / (1 + [S] / Km) converts one into the other, and it only fully applies when the Hill slope is 1.

Need the curve styled for a paper?

The dose-response curve generator turns a CSV or Excel file into a publication-style chart with a 4PL fit for each compound.

Open the dose-response curve generator
The IC50 calculator with the kinase example and Bottom fixed at 0: IC50 50.85 nM, the dose-response curve and the best-fit parameters